{ "id": "CVE-2022-32530", "sourceIdentifier": "cybersecurity@se.com", "published": "2022-06-24T13:15:07.287", "lastModified": "2024-11-21T07:06:34.283", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)" }, { "lang": "es", "value": "Una CWE-668: Se presenta una vulnerabilidad de Exposici\u00f3n de Recursos a Esferas Equivocadas que podr\u00eda causar que usuarios sean enga\u00f1ados, ocultando alarmas, mostrando la opci\u00f3n de conexi\u00f3n al servidor equivocada o la petici\u00f3n de control equivocada cuando un dispositivo m\u00f3vil ha sido comprometido por una aplicaci\u00f3n maliciosa. Producto afectado: Geo SCADA Mobile (Build 222 y anteriores)" } ], "metrics": { "cvssMetricV31": [ { "source": "cybersecurity@se.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L", "baseScore": 4.8, "baseSeverity": "MEDIUM", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "LOW" }, "exploitabilityScore": 1.3, "impactScore": 3.4 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "baseScore": 6.8, "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL" }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-668" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:geo_scada_mobile:*:*:*:*:*:android:*:*", "versionEndExcluding": "2020", "matchCriteriaId": "FAF12EB4-7FC7-4F3C-896B-7C4D997A5E07" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:geo_scada_mobile:2020:-:*:*:*:android:*:*", "matchCriteriaId": "94B3C2B6-EF85-4813-AD08-34B63BFEA46E" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:geo_scada_mobile:2020:build_222:*:*:*:android:*:*", "matchCriteriaId": "8D1B5192-7F9C-4F0D-BBCD-09CFCF4863CC" } ] } ] } ], "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf", "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] } ] }