{ "id": "CVE-2022-37012", "sourceIdentifier": "zdi-disclosures@trendmicro.com", "published": "2023-03-29T19:15:12.827", "lastModified": "2024-11-21T07:14:16.950", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ], "cvssMetricV30": [ { "source": "zdi-disclosures@trendmicro.com", "type": "Secondary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ] }, "weaknesses": [ { "source": "zdi-disclosures@trendmicro.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-911" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:unified-automation:opc_ua_c\\+\\+_demo_server:1.7.6.537:*:*:*:*:*:*:*", "matchCriteriaId": "389A3E3E-164D-44D8-95DF-DD21308ACA35" } ] } ] } ], "references": [ { "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt", "source": "zdi-disclosures@trendmicro.com", "tags": [ "Release Notes" ] }, { "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1030/", "source": "zdi-disclosures@trendmicro.com", "tags": [ "Third Party Advisory", "VDB Entry" ] }, { "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Release Notes" ] }, { "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1030/", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ] } ] }