{ "id": "CVE-2022-47375", "sourceIdentifier": "productcert@siemens.com", "published": "2023-12-12T12:15:10.797", "lastModified": "2024-11-21T07:31:51.270", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.\r\n\r\nThis could allow an attacker to create a buffer overflow and create a denial of service condition for the device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nSIMATIC PC-Station Plus (todas las versiones), \nSIMATIC S7-400 CPU 412-2 PN V7 (todas las versiones), \nSIMATIC S7-400 CPU 414-3 PN/DP V7 (todas las versiones), \nSIMATIC S7 -400 CPU 414F-3 PN/DP V7 (todas las versiones), \nSIMATIC S7-400 CPU 416-3 PN/DP V7 (todas las versiones), \nSIMATIC S7-400 CPU 416F-3 PN/DP V7 (todas las versiones), \nSINAMICS S120 (incl. variantes SIPLUS) (todas las versiones < V5.2 SP3 HF15), \nSIPLUS S7-400 CPU 414-3 PN/DP V7 (todas las versiones), \nSIPLUS S7-400 CPU 416-3 PN/DP V7 (todas las versiones) ). \nLos productos afectados no manejan correctamente los nombres de archivos largos. Esto podr\u00eda permitir a un atacante crear un desbordamiento del b\u00fafer y crear una condici\u00f3n de denegaci\u00f3n de servicio para el dispositivo." } ], "metrics": { "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-805" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-119" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:6es7412-2ek07-0ab0_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B9F039A6-AD1F-489C-9928-147973AE8DF3" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:6es7412-2ek07-0ab0:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D7EEE-9AC0-40D9-9C0A-2B098D152230" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:6es7414-3em07-0ab0_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "257AB2BE-EA5A-47D0-9677-D00FF682C170" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:6es7414-3em07-0ab0:-:*:*:*:*:*:*:*", "matchCriteriaId": "438FDBD7-1731-4D1B-ABA6-76F376054F07" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:6es7414-3fm07-0ab0_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0622ACDF-D82B-487C-84DF-75853A88184C" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:6es7414-3fm07-0ab0:-:*:*:*:*:*:*:*", "matchCriteriaId": "23B55825-D285-459F-AB82-110EC58D583C" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:6es7416-3es07-0ab0_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "268D8CA8-92BD-40BE-BCB0-8EBA4B724381" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:6es7416-3es07-0ab0:-:*:*:*:*:*:*:*", "matchCriteriaId": "877F922F-D395-4123-B4C2-DCA7D699EB22" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:6es7416-3fs07-0ab0_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1031CEF8-0F66-452E-8E79-BC4A5EDDB10E" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:6es7416-3fs07-0ab0:-:*:*:*:*:*:*:*", "matchCriteriaId": "DDA99580-AF0C-4837-B4DB-593C5A045129" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:6ag1414-3em07-7ab0_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "228593D4-10E2-4345-85F5-FE69E68722A3" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:6ag1414-3em07-7ab0:-:*:*:*:*:*:*:*", "matchCriteriaId": "D2066A76-56E4-41C4-9057-F1697B9ADAFE" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:6ag1416-3es07-7ab0_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BD7B48F6-B94E-4B65-A2A9-2B5BB333415B" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:6ag1416-3es07-7ab0:-:*:*:*:*:*:*:*", "matchCriteriaId": "41422165-ABEF-4F09-9E39-C4F89497894B" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDA8B933-D7E3-4E3B-AA1D-75AFC89EA730" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:*:*:*:*:*:*:*", "matchCriteriaId": "D61A6DA0-1328-4D6F-80A1-2A7CE369A7C9" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.8:*:*:*:*:*:*:*", "matchCriteriaId": "B46F2FCA-845B-4E65-AF8C-B924E55921B3" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.9:*:*:*:*:*:*:*", "matchCriteriaId": "0CD43CE2-ED05-4BBF-9553-04AB07D33F50" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.0:*:*:*:*:*:*:*", "matchCriteriaId": "DB8DD275-D4EA-426C-8611-C2083036A799" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1:*:*:*:*:*:*", "matchCriteriaId": "9EB60A1E-ABE0-4A1C-A2F0-C77E59DCF577" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1_hotfix1:*:*:*:*:*:*", "matchCriteriaId": "03224943-DCAF-4203-90BD-A6100745A3A8" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1_hotfix13:*:*:*:*:*:*", "matchCriteriaId": "59460788-9C30-444F-B0F5-B2ACB7B5CDCD" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*", "matchCriteriaId": "6622AE2E-81B0-419C-8C37-A7C56FB92745" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix1:*:*:*:*:*:*", "matchCriteriaId": "D8DFFEC3-B48B-4B47-83E4-B73383003F68" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix11:*:*:*:*:*:*", "matchCriteriaId": "10596147-76C0-4626-987B-AECA3D359C9F" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix7:*:*:*:*:*:*", "matchCriteriaId": "4B6DEC37-63E1-479C-91C5-A5339E5F4FAB" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3:*:*:*:*:*:*", "matchCriteriaId": "AD9434B6-29F3-445C-A3CA-57E2230622EA" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix1:*:*:*:*:*:*", "matchCriteriaId": "284207F1-E83D-4D32-8D0C-5D20126D0B11" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix13:*:*:*:*:*:*", "matchCriteriaId": "95DC883D-5792-4ECD-9A19-D97173FD2D96" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix6:*:*:*:*:*:*", "matchCriteriaId": "7ADD4FD1-F3E2-480A-AE4E-747AA744F8D6" }, { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix9:*:*:*:*:*:*", "matchCriteriaId": "E9DF3564-63E8-4B17-A2CD-799954C31B42" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:simatic_pc-station_plus_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EA49005-5CEB-4AC5-8E3A-6400650C4F1A" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:simatic_pc-station_plus:-:*:*:*:*:*:*:*", "matchCriteriaId": "D170B645-158D-443D-A565-FC44663DEA16" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf", "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] } ] }