{ "id": "CVE-2024-7847", "sourceIdentifier": "PSIRT@rockwellautomation.com", "published": "2024-10-14T14:15:12.020", "lastModified": "2024-10-15T12:57:46.880", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "VULNERABILITY DETAILS\n\nRockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82. \n\nA feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability." }, { "lang": "es", "value": "DETALLES DE LA VULNERABILIDAD Rockwell Automation utiliz\u00f3 las \u00faltimas versiones del sistema de puntuaci\u00f3n CVSS para evaluar las siguientes vulnerabilidades. Sharon Brizinov de Claroty Research - Team82 nos inform\u00f3 sobre las siguientes vulnerabilidades. Una caracter\u00edstica de los productos afectados permite a los usuarios preparar un archivo de proyecto con un script VBA integrado y se puede configurar para que se ejecute una vez que se haya abierto el archivo de proyecto sin intervenci\u00f3n del usuario. Esta caracter\u00edstica se puede utilizar de forma abusiva para enga\u00f1ar a un usuario leg\u00edtimo para que ejecute c\u00f3digo malicioso al abrir un archivo de proyecto RSP/RSS infectado. Si se explota, un actor de amenazas puede realizar una ejecuci\u00f3n remota de c\u00f3digo. Los dispositivos conectados tambi\u00e9n pueden verse afectados por la explotaci\u00f3n de esta vulnerabilidad." } ], "metrics": { "cvssMetricV40": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "baseScore": 8.8, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "HIGH", "attackRequirements": "NONE", "privilegesRequired": "NONE", "userInteraction": "PASSIVE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnAvailabilityImpact": "HIGH", "subConfidentialityImpact": "HIGH", "subIntegrityImpact": "HIGH", "subAvailabilityImpact": "HIGH", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirement": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "availabilityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED" } } ], "cvssMetricV31": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "baseScore": 7.7, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "HIGH", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 1.0, "impactScore": 6.0 } ] }, "weaknesses": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-345" } ] } ], "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1701.html", "source": "PSIRT@rockwellautomation.com" } ] }