{ "id": "CVE-2021-45546", "sourceIdentifier": "cve@mitre.org", "published": "2021-12-26T01:15:15.177", "lastModified": "2024-11-21T06:32:28.830", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a R7850 versiones anteriores a 1.0.5.74, a R7900P versiones anteriores a 1.4.2.84, a R7960P versiones anteriores a 1.4.2.84, a R8000 versiones anteriores a 1.0.4.74, a R8000P versiones anteriores a 1.4.2.84, a RAX200 versiones anteriores a 1.0.4.120, a RAX75 versiones anteriores a 1.0.4. 120, RAX80 versiones anteriores a 1.0.4.120, RBK752 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "metrics": { "cvssMetricV31": [ { "source": "cve@mitre.org", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "baseScore": 8.4, "baseSeverity": "HIGH", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 1.7, "impactScore": 6.0 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseScore": 8.8, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "baseScore": 6.5, "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "SINGLE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL" }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.0, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-77" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.0.5.74", "matchCriteriaId": "8491F80C-E57A-4862-B969-F43799A47D06" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.4.2.84", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.4.2.84", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.0.4.74", "matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.4.2.84", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.0.4.120", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.0.4.120", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.0.4.120", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.2.17.12", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.2.17.12", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.2.17.12", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.2.17.12", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.2.17.12", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.2.17.12", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86" } ] } ] } ], "references": [ { "url": "https://kb.netgear.com/000064524/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0566", "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ] }, { "url": "https://kb.netgear.com/000064524/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0566", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ] } ] }