{ "id": "CVE-2024-46891", "sourceIdentifier": "productcert@siemens.com", "published": "2024-11-12T13:15:09.693", "lastModified": "2024-11-12T15:35:11.240", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEC INS (todas las versiones < V1.0 SP2 Update 3). La aplicaci\u00f3n afectada no restringe adecuadamente el tama\u00f1o de los archivos de registro generados. Esto podr\u00eda permitir que un atacante remoto no autenticado active una gran cantidad de eventos registrados para agotar los recursos del sistema y crear una condici\u00f3n de denegaci\u00f3n de servicio." } ], "metrics": { "cvssMetricV40": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "baseScore": 6.9, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "NONE", "userInteraction": "NONE", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnAvailabilityImpact": "LOW", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "subAvailabilityImpact": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirement": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "availabilityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED" } } ], "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "baseScore": 5.3, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "LOW" }, "exploitabilityScore": 3.9, "impactScore": 1.4 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-400" } ] }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-125" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-915275.html", "source": "productcert@siemens.com" } ] }