{ "id": "CVE-2023-38527", "sourceIdentifier": "productcert@siemens.com", "published": "2023-08-08T10:15:15.923", "lastModified": "2024-08-13T08:15:06.110", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Parasolid V34.1 (Todas las versiones inferiores a V34.1.258), Parasolid V35.0 (Todas las versiones inferiores a V35.0.254), Teamcenter Visualization V14.1 (Todas las versiones inferiores a V14.1.0.11), Teamcenter Visualization V14.2 (Todas las versiones inferiores a V14.2.0.6), Teamcenter Visualization V14.3 (Todas las versiones inferiores a V14.3.0.3). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada al analizar archivos X_T especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual." } ], "metrics": { "cvssMetricV40": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "attackVector": "LOCAL", "attackComplexity": "HIGH", "attackRequirements": "NONE", "privilegesRequired": "NONE", "userInteraction": "PASSIVE", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "HIGH", "vulnerableSystemAvailability": "HIGH", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "subsequentSystemAvailability": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "safety": "NOT_DEFINED", "automatable": "NOT_DEFINED", "recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "baseScore": 7.3, "baseSeverity": "HIGH" } } ], "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 }, { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-125" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-125" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "34.1", "versionEndExcluding": "34.1.258", "matchCriteriaId": "E7751190-C386-451B-88B5-4BB4DCBFCE44" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "35.0", "versionEndExcluding": "35.0.254", "matchCriteriaId": "0B5F1A02-44EB-45AA-B071-764B64473313" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "14.1", "versionEndExcluding": "14.1.0.11", "matchCriteriaId": "9EF3388B-D057-4DB9-96AE-B6F4678FE5B8" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "14.2", "versionEndExcluding": "14.2.0.6", "matchCriteriaId": "7E1EFF45-5311-4E89-B736-271EF3C0C232" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "14.3", "versionEndExcluding": "14.3.0.3", "matchCriteriaId": "99F0D457-7D65-40DC-BCFA-339FA5648709" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html", "source": "productcert@siemens.com" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }