{ "id": "CVE-2024-41938", "sourceIdentifier": "productcert@siemens.com", "published": "2024-08-13T08:15:14.353", "lastModified": "2024-08-13T08:15:14.353", "vulnStatus": "Received", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEC NMS (All versions < V3.0). The importCertificate function of the SINEC NMS Control web application contains a path traversal vulnerability. This could allow an authenticated attacker it to delete arbitrary certificate files on the drive SINEC NMS is installed on." } ], "metrics": { "cvssMetricV40": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:L/VA:L/SC:N/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "attackVector": "NETWORK", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "HIGH", "userInteraction": "NONE", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "LOW", "vulnerableSystemAvailability": "LOW", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "LOW", "subsequentSystemAvailability": "LOW", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "safety": "NOT_DEFINED", "automatable": "NOT_DEFINED", "recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "baseScore": 5.1, "baseSeverity": "MEDIUM" } } ], "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:L", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "availabilityImpact": "LOW", "baseScore": 5.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.3, "impactScore": 2.7 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-22" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html", "source": "productcert@siemens.com" } ] }