{ "id": "CVE-2023-29413", "sourceIdentifier": "cybersecurity@se.com", "published": "2023-04-18T21:15:09.523", "lastModified": "2023-04-28T13:26:11.537", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 }, { "source": "cybersecurity@se.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-306" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "versionEndIncluding": "2.5-ga-01-22320", "matchCriteriaId": "D52617D6-0503-4B6B-A59D-441E0D1F4296" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*", "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0" }, { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6" }, { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7" }, { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968" }, { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "versionEndIncluding": "2.5-gs-01-22320", "matchCriteriaId": "1849E03C-445A-4225-AECD-B4A7502F5F3B" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*", "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0" }, { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6" }, { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7" }, { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968" }, { "vulnerable": false, "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C" } ] } ] } ], "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf", "source": "cybersecurity@se.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ] } ] }