{ "id": "CVE-2022-29032", "sourceIdentifier": "productcert@siemens.com", "published": "2022-05-20T13:15:15.743", "lastModified": "2022-05-26T22:45:32.993", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions < V13.3.0.3), Teamcenter Visualization V13.3 (All versions < V13.3.0.3), Teamcenter Visualization V14.0 (All versions < V14.0.0.1). The CGM_NIST_Loader.dll library contains a double free vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.3.0.3), Teamcenter Visualization versi\u00f3n V13.3 (Todas las versiones anteriores a V13.3.0.3), Teamcenter Visualization versi\u00f3n V14.0 (Todas las versiones anteriores a V14.0.0.1). La biblioteca CGM_NIST_Loader.dll contiene una vulnerabilidad de doble liberaci\u00f3n mientras analiza archivos CGM especialmente dise\u00f1ados. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 6.8 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-415" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-415" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "versionEndExcluding": "13.3.0.3", "matchCriteriaId": "3690D75E-B2DA-4B4F-A045-2361235993F5" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "13.3", "versionEndExcluding": "13.3.0.3", "matchCriteriaId": "A4D62687-5D71-43B9-AAB8-FC6890048FAC" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "14.0", "versionEndExcluding": "14.0.0.1", "matchCriteriaId": "7F603C96-3FE1-47F5-BC62-2CD68898BD37" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553086.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }