{ "id": "CVE-2022-22812", "sourceIdentifier": "cybersecurity@se.com", "published": "2022-02-09T23:15:19.433", "lastModified": "2022-02-16T18:36:54.277", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)" }, { "lang": "es", "value": "Una CWE-79: Se presenta una vulnerabilidad de Neutralizaci\u00f3n Inadecuada de Entradas Durante la Generaci\u00f3n de P\u00e1ginas Web (\"Cross-site Scripting\") que podr\u00eda causar un compromiso de la sesi\u00f3n web cuando un atacante inyecta y luego ejecuta c\u00f3digo JavaScript malicioso arbitrario dentro del navegador de destino. Producto afectado: spaceLYnk (versiones V2.6.2 y anteriores), Wiser for KNX (anteriormente homeLYnk) (versiones V2.6.2 y anteriores), fellerLYnk (V2.6.2 y anteriores)" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 2.7 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "availabilityImpact": "NONE", "baseScore": 4.3 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-79" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "2.6.2", "matchCriteriaId": "64C0D5C8-3559-4591-8F88-A9D6E3DFA9E4" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7B2FBBD-C461-47EF-A912-E445C063DED9" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "2.6.2", "matchCriteriaId": "BD308EE6-41C3-4D93-A2A5-9D7EFF3A8413" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:*", "matchCriteriaId": "EAF53585-8B87-4609-991E-30B56B601DEA" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:fellerlynk_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "2.6.2", "matchCriteriaId": "89174639-40D3-4A31-8357-7C497BCF2895" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:fellerlynk:-:*:*:*:*:*:*:*", "matchCriteriaId": "FC947F97-7E49-475F-84E6-29D7A6DF50CB" } ] } ] } ], "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04", "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }