{ "id": "CVE-2022-43397", "sourceIdentifier": "productcert@siemens.com", "published": "2022-11-08T11:15:11.880", "lastModified": "2024-11-21T07:26:24.033", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)" }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en: \nParasolid V34.0 (Todas las versiones < V34.0.252), \nParasolid V34.1 (Todas las versiones < V34.1.242), \nParasolid V35.0 (Todas las versiones < V35.0.170), \nSimcenter Femap (Todas las versiones < V2023.1). \nLa aplicaci\u00f3n afectada contiene una escritura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado mientras analiza archivos X_T especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-17854)" } ], "metrics": { "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-787" } ] }, { "source": "nvd@nist.gov", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-787" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "34.0", "versionEndExcluding": "34.0.252", "matchCriteriaId": "F0D9079D-6138-4602-A982-9BC4ECBC35E7" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "34.1", "versionEndExcluding": "34.1.242", "matchCriteriaId": "4C486991-A1C0-4815-AAD6-163464D711AA" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "35.0", "versionEndExcluding": "35.0.170", "matchCriteriaId": "EA2114FD-BB07-4C24-98B1-928A510565BB" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf", "source": "productcert@siemens.com" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf", "source": "productcert@siemens.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ] }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf", "source": "af854a3a-2127-422b-91ae-364da2661108" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ] } ] }