{ "id": "CVE-2006-1538", "sourceIdentifier": "cve@mitre.org", "published": "2006-03-30T11:02:00.000", "lastModified": "2018-10-18T16:33:19.140", "vulnStatus": "Modified", "evaluatorSolution": "Physical access to the device or hardware token is required to perform\r\nthe attack.", "descriptions": [ { "lang": "en", "value": "The Enova X-Wall ASIC encrypts with a key obtained via Microwire from a serial EEPROM that stores the key in cleartext, which allows local users with physical access to obtain the key by reading and duplicating an EEPROM that is located on a hardware token, or by sniffing the Microwire bus." } ], "metrics": { "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:L/AC:L/Au:N/C:C/I:N/A:N", "accessVector": "LOCAL", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "COMPLETE", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.9 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 3.9, "impactScore": 6.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:enova:x-wall_asic:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C5C3F73-3BFB-4603-A5C2-6F1551924B30" } ] } ] } ], "references": [ { "url": "http://securityreason.com/securityalert/648", "source": "cve@mitre.org" }, { "url": "http://www.hexview.com/docs/20060328-1.txt", "source": "cve@mitre.org" }, { "url": "http://www.securityfocus.com/archive/1/429253/100/0/threaded", "source": "cve@mitre.org" }, { "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/25527", "source": "cve@mitre.org" } ] }