{ "id": "CVE-2021-21577", "sourceIdentifier": "security_alert@emc.com", "published": "2021-08-03T16:15:07.867", "lastModified": "2021-08-09T20:06:37.293", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Dell EMC iDRAC9 versions prior to 4.40.40.00 contain a DOM-based cross-site scripting vulnerability. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link." }, { "lang": "es", "value": "Dell EMC iDRAC9 versiones anteriores a 4.40.40.00 contienen una vulnerabilidad de tipo cross-site scripting basada en DOM. Un atacante remoto podr\u00eda explotar potencialmente esta vulnerabilidad para ejecutar HTML o JavaScript maliciosos en el navegador de una v\u00edctima al enga\u00f1arla para que siga un enlace especialmente dise\u00f1ado" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 2.7 }, { "source": "security_alert@emc.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 2.7 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "availabilityImpact": "NONE", "baseScore": 4.3 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-79" } ] }, { "source": "security_alert@emc.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-79" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:dell:emc_idrac9_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "4.40.40.00", "matchCriteriaId": "8677A5D5-756F-411F-B0D7-2E06105F3B56" } ] } ] } ], "references": [ { "url": "https://www.dell.com/support/kbdoc/000189193", "source": "security_alert@emc.com", "tags": [ "Vendor Advisory" ] } ] }