{ "id": "CVE-2021-26730", "sourceIdentifier": "prodsec@nozominetworks.com", "published": "2022-10-24T14:15:48.243", "lastModified": "2022-12-03T15:08:23.500", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A stack-based buffer overflow vulnerability in a subfunction of the Login_handler_func function of spx_restservice allows an attacker to execute arbitrary code with the same privileges as the server user (root). This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.10.0." }, { "lang": "es", "value": "Una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria en una subfunci\u00f3n de la funci\u00f3n Login_handler_func de spx_restservice permite a un atacante ejecutar c\u00f3digo arbitrario con los mismos privilegios que el usuario del servidor (root). Este problema afecta: Lanner Inc IAC-AST2500A versi\u00f3n de firmware est\u00e1ndar 1.10.0" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 }, { "source": "prodsec@nozominetworks.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 6.0 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-787" } ] }, { "source": "prodsec@nozominetworks.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-121" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:lannerinc:iac-ast2500a_firmware:1.10.0:*:*:*:*:*:*:*", "matchCriteriaId": "8DD71184-078B-4B7E-BCB5-11E55B5928B7" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:lannerinc:iac-ast2500a:-:*:*:*:*:*:*:*", "matchCriteriaId": "9007683B-45DA-471A-9CCB-A587DED8D973" } ] } ] } ], "references": [ { "url": "https://www.nozominetworks.com/blog/vulnerabilities-in-bmc-firmware-affect-ot-iot-device-security-part-1/", "source": "prodsec@nozominetworks.com", "tags": [ "Third Party Advisory" ] }, { "url": "https://www.nozominetworks.com/labs/vulnerability-advisories/cve-2021-26730/", "source": "prodsec@nozominetworks.com", "tags": [ "Third Party Advisory" ] } ] }