{ "id": "CVE-2021-31338", "sourceIdentifier": "productcert@siemens.com", "published": "2021-08-19T16:15:12.243", "lastModified": "2021-08-26T11:52:17.950", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.0 SP1). Affected devices allow to modify configuration settings over an unauthenticated channel. This could allow a local attacker to escalate privileges and execute own code on the device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Client (Todas las versiones anteriores a V3.0 SP1). Los dispositivos afectados permiten modificar los ajustes de configuraci\u00f3n a trav\u00e9s de un canal no autenticado. Esto podr\u00eda permitir a un atacante local escalar privilegios y ejecutar c\u00f3digo propio en el dispositivo." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "accessVector": "LOCAL", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 4.6 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 3.9, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-15" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinema_remote_connect:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.0", "matchCriteriaId": "9EE01078-3C5D-4BF9-9939-5692FF11F30A" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinema_remote_connect:3.0:-:*:*:*:*:*:*", "matchCriteriaId": "1F2BC5B5-429F-4C8F-ACCE-E544868F3A88" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816035.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }