{ "id": "CVE-2021-37207", "sourceIdentifier": "productcert@siemens.com", "published": "2021-11-09T12:15:09.867", "lastModified": "2021-11-11T02:34:55.913", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SENTRON powermanager V3 (All versions). The affected application assigns improper access rights to a specific folder containing configuration files. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SENTRON powermanager versi\u00f3n V3 (Todas las versiones). La aplicaci\u00f3n afectada asigna derechos de acceso inapropiados a una carpeta espec\u00edfica que contiene archivos de configuraci\u00f3n. Esto podr\u00eda permitir a un atacante local autenticado inyectar c\u00f3digo arbitrario y escalar privilegios" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "accessVector": "LOCAL", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "availabilityImpact": "COMPLETE", "baseScore": 7.2 }, "baseSeverity": "HIGH", "exploitabilityScore": 3.9, "impactScore": 10.0, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-732" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sentron_powermanager_3:*:*:*:*:*:*:*:*", "versionStartIncluding": "3.0", "versionEndIncluding": "3.6", "matchCriteriaId": "9A8CB469-773F-4583-95B9-EC5711B1A7E6" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-537983.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }