{ "id": "CVE-2021-45626", "sourceIdentifier": "cve@mitre.org", "published": "2021-12-26T01:15:19.007", "lastModified": "2022-01-05T18:20:16.690", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK20 before 2.6.1.36, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, and RBS50Y before 2.6.1.40." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK20 versiones anteriores a 2.6.1.36, RBR20 versiones anteriores a 2.6.1.36, RBS20 versiones anteriores a 2.6.1.38, RBK40 versiones anteriores a 2.6.1.36, RBR40 versiones anteriores a 2.6.1.36, RBS40 versiones anteriores a 2.6.1.38, RBK50 versiones anteriores a 2.6.1.40, RBR50 versiones anteriores a 2.6.1.40, RBS50 versiones anteriores a 2.6.1.40 y RBS50Y versiones anteriores a 2.6.1.40" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 }, { "source": "cve@mitre.org", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 2.8, "impactScore": 6.0 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "accessVector": "ADJACENT_NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 5.8 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 6.5, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-77" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.6.1.38", "matchCriteriaId": "E72FDDB4-0802-467B-A255-06C8CE1A0B92" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.6.1.36", "matchCriteriaId": "C80BEFF8-7094-4F21-B9E7-EE5C8B9DF3B3" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.6.1.38", "matchCriteriaId": "04F03BE5-1440-4BC4-B902-97E702ED0ADF" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.6.1.38", "matchCriteriaId": "09631703-25CD-40CB-80A8-AADD43939507" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.6.1.36", "matchCriteriaId": "1E21623E-9977-486F-93B1-858FC407E9D1" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.6.1.38", "matchCriteriaId": "A32769CF-7D0A-4A3F-AF20-6202CA0C6870" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.6.1.40", "matchCriteriaId": "A0E3BFCB-BFF8-4722-BE48-5FA93CACD3AD" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.6.1.40", "matchCriteriaId": "39D6318D-F5A2-4469-B508-075F2825F0FA" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.6.1.40", "matchCriteriaId": "1F44708A-C946-4E0F-9D6C-A91AFB4C9EF3" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:netgear:rbs50y_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "2.6.1.40", "matchCriteriaId": "E9E75105-CB35-4983-8CC0-98699AAA63BE" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:netgear:rbs50y:-:*:*:*:*:*:*:*", "matchCriteriaId": "27F93A76-6EFF-4DA6-9129-4792E2C125D4" } ] } ] } ], "references": [ { "url": "https://kb.netgear.com/000064068/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2019-0152", "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ] } ] }