{ "id": "CVE-2017-5240", "sourceIdentifier": "cve@rapid7.con", "published": "2017-05-03T16:59:00.190", "lastModified": "2017-05-16T01:32:29.063", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Editions of Rapid7 AppSpider Pro prior to version 6.14.060 contain a heap-based buffer overflow in the FLAnalyzer.exe component. A malicious or malformed Flash source file can cause a denial of service condition when parsed by this component, causing the application to crash." }, { "lang": "es", "value": "Las ediciones de Rapid7 AppSpider Pro anteriores a la versi\u00f3n 6.14.060 contienen un desbordamiento de buffer basado en memoria din\u00e1mica en el componente FLAnalyzer.exe. Un archivo de c\u00f3digo fuente Flash malicioso o mal formado puede causar una condici\u00f3n de denegaci\u00f3n de servicio cuando se analiza por este componente, provocando que la aplicaci\u00f3n se bloquee." } ], "metrics": { "cvssMetricV30": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 10.0, "impactScore": 2.9, "acInsufInfo": true, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-119" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:rapid7:appspider_pro:*:*:*:*:*:*:*:*", "versionEndIncluding": "6.14.059", "matchCriteriaId": "C33EEBA9-00DD-4297-8814-CCA32F374DFC" } ] } ] } ], "references": [ { "url": "https://community.rapid7.com/docs/DOC-3631", "source": "cve@rapid7.con", "tags": [ "Release Notes", "Vendor Advisory" ] } ] }