{ "id": "CVE-2019-10976", "sourceIdentifier": "ics-cert@hq.dhs.gov", "published": "2019-07-26T00:15:11.403", "lastModified": "2019-10-09T23:45:08.527", "vulnStatus": "Modified", "descriptions": [ { "lang": "en", "value": "Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user opens the file, the attacker could read arbitrary files." }, { "lang": "es", "value": "FR Configurator2 de Mitsubishi Electric, versi\u00f3n 1.16S y anteriores. Esta vulnerabilidad es activada cuando la entrada pasada hacia el analizador XML no es saneada mientras se analiza el proyecto XML y/o el archivo de plantilla (.frc2). Una vez que un usuario abre el archivo, el atacante podr\u00eda leer archivos arbitrarios." } ], "metrics": { "cvssMetricV30": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.8, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-611" } ] }, { "source": "ics-cert@hq.dhs.gov", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-611" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:mitsubishielectric:electric_fr_configurator2_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.16s", "matchCriteriaId": "6C97C383-D103-4064-A5EC-5F998E7E8DF3" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:mitsubishielectric:electric_fr_configurator2:-:*:*:*:*:*:*:*", "matchCriteriaId": "795E70FF-FD1A-4249-BB49-1CB3233EF6F6" } ] } ] } ], "references": [ { "url": "https://www.us-cert.gov/ics/advisories/icsa-19-204-01", "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ] } ] }