{ "id": "CVE-2019-11523", "sourceIdentifier": "cve@mitre.org", "published": "2019-06-06T20:29:02.697", "lastModified": "2020-08-24T17:37:01.140", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Anviz Global M3 Outdoor RFID Access Control executes any command received from any source. No authentication/encryption is done. Attackers can fully interact with the device: for example, send the \"open door\" command, download the users list (which includes RFID codes and passcodes in cleartext), or update/create users. The same attack can be executed on a local network and over the internet (if the device is exposed on a public IP address)." }, { "lang": "es", "value": "Anviz Global M3 Outdoor RFID Access Control ejecuta cualquier comando recibido de cualquier fuente. No se realiza identificaci\u00f3n / cifrado. Los atacantes pueden interactuar completamente con el dispositivo: por ejemplo, enviar el comando \"open door\", descargar la lista de usuarios (que incluye c\u00f3digos RFID y c\u00f3digos de acceso en texto claro), o actualizar / crear usuarios. El mismo ataque se puede ejecutar en una red local y en Internet (si el dispositivo est\u00e1 expuesto en una direcci\u00f3n IP p\u00fablica)." } ], "metrics": { "cvssMetricV30": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 7.5 }, "baseSeverity": "HIGH", "exploitabilityScore": 10.0, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-306" }, { "lang": "en", "value": "CWE-311" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:anviz:m3_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "6C0504E8-2856-4962-9EC5-DBB7134F5DA2" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:anviz:m3:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BDD1A47-2852-4A4A-A401-4C134A696E9D" } ] } ] } ], "references": [ { "url": "https://github.com/wizlab-it/anviz-m3-rfid-cve-2019-11523-poc", "source": "cve@mitre.org", "tags": [ "Mitigation", "Exploit", "Third Party Advisory" ] } ] }