{ "id": "CVE-2019-13920", "sourceIdentifier": "productcert@siemens.com", "published": "2019-09-13T17:15:11.867", "lastModified": "2019-10-09T23:46:37.077", "vulnStatus": "Modified", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a logged-in user to the application. The vulnerability could allow switching the connectivity state of a user or a device. At the time of advisory publication no public exploitation of this security vulnerability was known." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V2.0 SP1). Algunas partes de la aplicaci\u00f3n web no est\u00e1n protegidas contra ataques de tipo Cross Site Request Forgery (CSRF). La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante que pueda desencadenar peticiones de un usuario registrado en la aplicaci\u00f3n. La vulnerabilidad podr\u00eda permitir cambiar el estado de conectividad de un usuario o dispositivo. Al momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda una explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 1.4 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "availabilityImpact": "NONE", "baseScore": 4.3 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-352" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-352" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "versionEndIncluding": "2.0", "matchCriteriaId": "380C606D-43A0-4362-9A5E-BC7320890196" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:2.0:hf1:*:*:*:*:*:*", "matchCriteriaId": "33B706BB-C3D7-4BAA-A140-A7AF962F7141" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }