{ "id": "CVE-2020-9261", "sourceIdentifier": "psirt@huawei.com", "published": "2020-07-06T19:15:12.823", "lastModified": "2020-07-09T15:14:45.863", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "HUAWEI Mate 30 with versions earlier than 10.1.0.150(C00E136R5P3) have a type confusion vulnerability. The system does not properly check and transform the type of certain variable, the attacker tricks the user into installing then running a crafted application, successful exploit could cause code execution." }, { "lang": "es", "value": "HUAWEI Mate 30 con versiones anteriores a 10.1.0.150(C00E136R5P3), presenta una vulnerabilidad de confusi\u00f3n de tipo. El sistema no comprueba y ni transforma apropiadamente el tipo de determinada variable, el atacante enga\u00f1a al usuario para que instale y luego ejecute una aplicaci\u00f3n dise\u00f1ada, una explotaci\u00f3n con \u00e9xito podr\u00eda causar una ejecuci\u00f3n de c\u00f3digo" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 6.8 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-843" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:huawei:mate_30_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "10.1.0.150\\(c00e136r5p3\\)", "matchCriteriaId": "EEB3F33A-CBB7-47B1-9208-E6FEFB4B48D8" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:huawei:mate_30:-:*:*:*:*:*:*:*", "matchCriteriaId": "40B08C1D-444B-4C8B-B7F9-60CA9B2A8D50" } ] } ] } ], "references": [ { "url": "https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20200701-05-smartphone-en", "source": "psirt@huawei.com", "tags": [ "Vendor Advisory" ] } ] }