{ "id": "CVE-2021-22716", "sourceIdentifier": "cybersecurity@se.com", "published": "2021-04-13T19:15:14.210", "lastModified": "2024-11-21T05:50:31.200", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)" }, { "lang": "es", "value": "Una CWE-732: Asignaci\u00f3n incorrecta de permisos para recursos cr\u00edticos que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo cuando un usuario sin privilegios modifica un archivo. Producto afectado: C-Bus Toolkit (V1.15.9 y anteriores)" } ], "metrics": { "cvssMetricV31": [ { "source": "cybersecurity@se.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "baseScore": 4.6, "accessVector": "LOCAL", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL" }, "baseSeverity": "MEDIUM", "exploitabilityScore": 3.9, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-732" } ] }, { "source": "nvd@nist.gov", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-732" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*", "versionEndIncluding": "1.15.7", "matchCriteriaId": "F0CC2C60-78DD-4959-B70F-CF0A3073FC56" } ] } ] } ], "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf", "source": "cybersecurity@se.com" }, { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01", "source": "cybersecurity@se.com" }, { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf", "source": "af854a3a-2127-422b-91ae-364da2661108" }, { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01", "source": "af854a3a-2127-422b-91ae-364da2661108" } ] }