{ "id": "CVE-2021-37190", "sourceIdentifier": "productcert@siemens.com", "published": "2021-09-14T11:15:25.940", "lastModified": "2021-09-23T19:18:22.230", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software has an information disclosure vulnerability that could allow an attacker to retrieve VPN connection for a known user." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V3.0 SP2). El software afectado presenta una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n que podr\u00eda permitir a un atacante recuperar la conexi\u00f3n VPN de un usuario conocido" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 1.4 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "accessVector": "ADJACENT_NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3 }, "baseSeverity": "LOW", "exploitabilityScore": 6.5, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-200" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.0", "matchCriteriaId": "F65F9901-F4BD-4484-9749-D5022245D686" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:-:*:*:*:*:*:*", "matchCriteriaId": "4F03BAD5-7B90-4212-ACBC-3C878C02CDAA" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "E5BACE03-50A7-4279-8CA5-2BB95224D485" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }