{ "id": "CVE-2025-27397", "sourceIdentifier": "productcert@siemens.com", "published": "2025-03-11T10:15:19.083", "lastModified": "2025-03-11T10:15:19.083", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit user controlled paths to which logs are written and from where they are read.\r\nThis could allow an authenticated highly-privileged remote attacker to read and write arbitrary files in the filesystem, if and only if the malicious path ends with 'log' ." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (todas las versiones < V4.0). Los dispositivos afectados no limitan adecuadamente las rutas controladas por el usuario en las que se escriben los registros y desde d\u00f3nde se leen. Esto podr\u00eda permitir que un atacante remoto autenticado y con privilegios elevados lea y escriba archivos arbitrarios en el sistema de archivos, siempre y cuando la ruta maliciosa termine con 'log'." } ], "metrics": { "cvssMetricV40": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "baseScore": 5.1, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "HIGH", "userInteraction": "NONE", "vulnConfidentialityImpact": "LOW", "vulnIntegrityImpact": "LOW", "vulnAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "subAvailabilityImpact": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirement": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "availabilityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED" } } ], "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N", "baseScore": 3.8, "baseSeverity": "LOW", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE" }, "exploitabilityScore": 1.2, "impactScore": 2.5 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-22" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-075201.html", "source": "productcert@siemens.com" } ] }