{ "id": "CVE-2023-41032", "sourceIdentifier": "productcert@siemens.com", "published": "2023-09-12T10:15:29.690", "lastModified": "2024-02-16T14:25:44.303", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.253), Parasolid V35.1 (All versions < V35.1.184), Parasolid V36.0 (All versions < V36.0.142), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21263)" }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Parasolid V34.1 (todas las versiones < V34.1.258), Parasolid V35.0 (todas las versiones < V35.0.253), Parasolid V35.1 (todas las versiones < V35.1.184), Parasolid V36.0 (todas las versiones < V36.0.142). La aplicaci\u00f3n afectada contiene una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analiza archivos X_T especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-21263)" } ], "metrics": { "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-787" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-787" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "34.1", "versionEndExcluding": "34.1.258", "matchCriteriaId": "E7751190-C386-451B-88B5-4BB4DCBFCE44" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "35.0", "versionEndExcluding": "35.0.253", "matchCriteriaId": "0CC7B08D-C9CF-4B68-90A8-8D2DF3CB5154" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "35.1", "versionEndExcluding": "35.1.184", "matchCriteriaId": "3881FB7A-8951-48F6-A948-7C670C11B2B3" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "36.0", "versionEndExcluding": "36.0.142", "matchCriteriaId": "B2873D5B-2501-4B02-8B68-347B69FC8D43" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*", "versionStartIncluding": "2301.0", "versionEndExcluding": "2301.0003", "matchCriteriaId": "FC710071-C7AC-4ED0-9550-5FBE8FCD37AE" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*", "versionStartIncluding": "2306.0", "versionEndExcluding": "2306.0001", "matchCriteriaId": "8E84C2D3-EF31-46E9-884A-7EB00B515D23" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf", "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf", "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://www.bentley.com/advisories/be-2023-0004/", "source": "productcert@siemens.com", "tags": [ "Third Party Advisory" ] } ] }