{ "id": "CVE-2023-33122", "sourceIdentifier": "productcert@siemens.com", "published": "2023-06-13T09:15:18.380", "lastModified": "2023-06-22T00:05:51.170", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted CGM file. This vulnerability could allow an attacker to disclose sensitive information." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.8, "impactScore": 3.6 }, { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "baseSeverity": "LOW" }, "exploitabilityScore": 1.8, "impactScore": 1.4 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-125" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-125" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "versionEndExcluding": "14.2.0.3", "matchCriteriaId": "64B11DAF-8FFB-4696-85E5-67853B8A91F4" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "13.2.0", "versionEndExcluding": "13.2.0.13", "matchCriteriaId": "FC06105E-8D31-4AFD-88C6-2E58D01CFFE8" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "13.3.0", "versionEndExcluding": "13.3.0.10", "matchCriteriaId": "CAC2B735-3298-4B79-B98F-21916EE7926F" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "14.0", "versionEndExcluding": "14.0.0.6", "matchCriteriaId": "63AC2AB5-3593-4922-A4CC-E5E0E35DE071" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "14.1", "versionEndExcluding": "14.1.0.8", "matchCriteriaId": "F7D64A7C-AF27-4E09-9455-98BBF231CAF5" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "14.2", "versionEndExcluding": "14.2.0.3", "matchCriteriaId": "A5D5D267-7DE4-4116-878D-4422D9B5E7FD" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }