{ "id": "CVE-2019-19277", "sourceIdentifier": "productcert@siemens.com", "published": "2020-03-10T20:15:18.727", "lastModified": "2021-11-03T18:43:01.287", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIPORT MP (All versions < 3.1.4). Vulnerable versions of the device allow the creation of special accounts (\"service users\") with administrative privileges that could enable a remote authenticated attacker to perform actions that are not visible to other users of the system, such as granting persons access to a secured area." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIPORT MP (Todas las versiones anteriores a la versi\u00f3n 3.1.4). Las versiones vulnerables del dispositivo permiten la creaci\u00f3n de cuentas especiales (\"service users\") con privilegios administrativos que podr\u00edan permitir a un atacante autenticado remoto llevar a cabo acciones que no son visibles para otros usuarios del sistema, tales como otorgar a las personas acceso a un \u00e1rea segura." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.2, "impactScore": 5.2 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "SINGLE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "NONE", "baseScore": 5.5 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.0, "impactScore": 4.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-778" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:siport_mp:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.1.4", "matchCriteriaId": "CA1E874D-BAFE-4956-860B-271187FBB2D1" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978558.pdf", "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-08", "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ] } ] }