{ "id": "CVE-2023-26205", "sourceIdentifier": "psirt@fortinet.com", "published": "2023-11-14T18:15:28.260", "lastModified": "2023-11-20T17:58:52.160", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "An improper access control vulnerability\u00a0[CWE-284] in FortiADC automation feature 7.1.0 through 7.1.2, 7.0 all versions, 6.2 all versions, 6.1 all versions may allow an authenticated\u00a0low-privileged attacker to escalate their privileges to super_admin via a specific crafted configuration of fabric automation CLI script." }, { "lang": "es", "value": "Una vulnerabilidad de control de acceso inadecuado [CWE-284] en la funci\u00f3n de automatizaci\u00f3n FortiADC 7.1.0 a 7.1.2, 7.0 todas las versiones, 6.2 todas las versiones, 6.1 todas las versiones puede permitir que un atacante autenticado con pocos privilegios escale sus privilegios a super_admin a trav\u00e9s de una configuraci\u00f3n manipulada del script CLI de automatizaci\u00f3n de fabric." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 }, { "source": "psirt@fortinet.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.2 } ] }, "weaknesses": [ { "source": "psirt@fortinet.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-284" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiadc:*:*:*:*:*:*:*:*", "versionStartIncluding": "6.1.0", "versionEndIncluding": "6.1.6", "matchCriteriaId": "D31CF79E-6C56-4CD0-9DD2-FBB48D503786" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiadc:*:*:*:*:*:*:*:*", "versionStartIncluding": "6.2.0", "versionEndIncluding": "6.2.6", "matchCriteriaId": "F5275C5C-B6FD-4456-B143-ECDD282150C4" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiadc:*:*:*:*:*:*:*:*", "versionStartIncluding": "7.0.0", "versionEndIncluding": "7.0.5", "matchCriteriaId": "302D8FF0-69B6-451A-9B5B-E28B2FAA30D8" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiadc:7.1.0:*:*:*:*:*:*:*", "matchCriteriaId": "B35D8D53-448B-474C-B7CB-324CB4ED7A82" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiadc:7.1.1:*:*:*:*:*:*:*", "matchCriteriaId": "933701AE-43E3-4260-973B-4EA09C375965" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiadc:7.1.2:*:*:*:*:*:*:*", "matchCriteriaId": "7F3029D7-4C37-4468-9CCD-45C7259EFF2C" } ] } ] } ], "references": [ { "url": "https://fortiguard.com/psirt/FG-IR-22-292", "source": "psirt@fortinet.com", "tags": [ "Vendor Advisory" ] } ] }