{ "id": "CVE-2024-26276", "sourceIdentifier": "productcert@siemens.com", "published": "2024-04-09T09:15:24.457", "lastModified": "2024-08-13T08:15:09.880", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones < V2312.0004), Parasolid V35.1 (Todas las versiones < V35.1.254), Parasolid V36.0 (Todas las versiones < V36.0.207), Parasolid V36.1 (Todas las versiones < V36.1.147), Teamcenter Visualization V14.2 (todas las versiones), Teamcenter Visualization V14.3 (todas las versiones < V14.3.0.9), Teamcenter Visualization V2312 (todas las versiones < V2312.0004). La aplicaci\u00f3n afectada contiene una vulnerabilidad de agotamiento de pila mientras analiza un archivo X_T especialmente manipulado. Esto podr\u00eda permitir que un atacante provoque una condici\u00f3n de denegaci\u00f3n de servicio." } ], "metrics": { "cvssMetricV40": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "attackVector": "LOCAL", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "NONE", "userInteraction": "PASSIVE", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE", "vulnerableSystemAvailability": "LOW", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "subsequentSystemAvailability": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "safety": "NOT_DEFINED", "automatable": "NOT_DEFINED", "recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "baseScore": 4.8, "baseSeverity": "MEDIUM" } } ], "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "LOW", "baseScore": 3.3, "baseSeverity": "LOW" }, "exploitabilityScore": 1.8, "impactScore": 1.4 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-770" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html", "source": "productcert@siemens.com" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html", "source": "productcert@siemens.com" } ] }