{ "id": "CVE-2024-2983", "sourceIdentifier": "cna@vuldb.com", "published": "2024-03-27T16:15:10.450", "lastModified": "2024-05-17T02:38:40.503", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda FH1202 1.2.0.14(408) y clasificada como cr\u00edtica. La funci\u00f3n formSetClientState del archivo /goform/SetClientState es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento ID de dispositivo/limitSpeed/limitSpeedUp provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-258152. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "metrics": { "cvssMetricV31": [ { "source": "cna@vuldb.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "cna@vuldb.com", "type": "Secondary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "SINGLE", "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "availabilityImpact": "COMPLETE", "baseScore": 9.0 }, "baseSeverity": "HIGH", "exploitabilityScore": 8.0, "impactScore": 10.0, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "cna@vuldb.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-121" } ] } ], "references": [ { "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formSetClientState.md", "source": "cna@vuldb.com" }, { "url": "https://vuldb.com/?ctiid.258152", "source": "cna@vuldb.com" }, { "url": "https://vuldb.com/?id.258152", "source": "cna@vuldb.com" }, { "url": "https://vuldb.com/?submit.301274", "source": "cna@vuldb.com" } ] }