{ "id": "CVE-2024-39875", "sourceIdentifier": "productcert@siemens.com", "published": "2024-07-09T12:15:19.803", "lastModified": "2024-07-09T18:19:14.047", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows authenticated, low privilege users with the 'Manage own remote connections' permission to retrieve details about other users and group memberships." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (todas las versiones < V3.2 SP1). La aplicaci\u00f3n afectada permite a los usuarios autenticados y con privilegios bajos, con el permiso \"Manage own remote connections\", recuperar detalles sobre otros usuarios y membres\u00edas de grupos." } ], "metrics": { "cvssMetricV40": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "attackVector": "NETWORK", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "LOW", "userInteraction": "NONE", "vulnerableSystemConfidentiality": "LOW", "vulnerableSystemIntegrity": "NONE", "vulnerableSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "subsequentSystemAvailability": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "safety": "NOT_DEFINED", "automatable": "NOT_DEFINED", "recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "baseScore": 5.3, "baseSeverity": "MEDIUM" } } ], "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 1.4 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-732" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html", "source": "productcert@siemens.com" } ] }