{ "id": "CVE-2022-30232", "sourceIdentifier": "cybersecurity@se.com", "published": "2022-06-02T23:15:07.443", "lastModified": "2022-06-13T14:26:13.907", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)" }, { "lang": "es", "value": "Una CWE-20: Se presenta una vulnerabilidad de Comprobaci\u00f3n de Entrada Inapropiada que podr\u00eda causar una potencial ejecuci\u00f3n de c\u00f3digo remota cuando un atacante es capaz de interceptar y modificar una petici\u00f3n en la misma red o presenta acceso de configuraci\u00f3n a un dispositivo ION en la red. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 }, { "source": "cybersecurity@se.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.0, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.1, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "SINGLE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 6.5 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.0, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-20" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion_setup_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "3.2.22096.01", "matchCriteriaId": "B1A4B3A2-BAB3-4C23-99B5-9902786DA40E" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion_setup:-:*:*:*:*:*:*:*", "matchCriteriaId": "0860D069-9B26-437E-A156-61413BECE043" } ] } ] } ], "references": [ { "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-01/", "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }