{ "id": "CVE-2023-45601", "sourceIdentifier": "productcert@siemens.com", "published": "2023-10-10T11:15:13.247", "lastModified": "2023-10-12T00:44:25.833", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)" }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Parasolid V35.0 (Todas las versiones < V35.0.262), \nParasolid V35.1 (Todas las versiones < V35.1.250), \nParasolid V36.0 (Todas las versiones < V36.0.169), \nTecnomatix Plant Simulation V2201 ( Todas las versiones < V2201.0009),\nTecnomatix Plant Simulator V2302 (Todas las versiones < V2302.0003). \nLas aplicaciones afectadas contienen una vulnerabilidad de desbordamiento de pila al analizar archivos IGS especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-21290)" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 }, { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-787" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-121" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "35.0", "versionEndExcluding": "35.0.262", "matchCriteriaId": "1C96074D-757B-4A3F-8B04-504D52DBE0EE" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "35.1", "versionEndExcluding": "35.1.250", "matchCriteriaId": "78258279-F7F6-4057-8AE2-AF64387B04BB" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "36.0", "versionEndExcluding": "36.0.169", "matchCriteriaId": "97086FB9-6392-4B6D-8CD4-EA780AE4DD05" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*", "versionStartIncluding": "2201", "versionEndExcluding": "2201.0009", "matchCriteriaId": "ECCC6F17-BB3D-4FD0-B277-5DD86EB4C9F7" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*", "versionStartIncluding": "2302", "versionEndExcluding": "2302.0003", "matchCriteriaId": "C29307AD-B728-41D3-9D57-FD5D1D51ACFA" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }