{ "id": "CVE-2020-26198", "sourceIdentifier": "security_alert@emc.com", "published": "2020-12-16T16:15:13.883", "lastModified": "2024-11-21T05:19:30.567", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link." }, { "lang": "es", "value": "Dell EMC iDRAC9 versiones anteriores a 4.32.10.00 y 4.40.00.00, contienen una vulnerabilidad de tipo cross-site scripting reflejada en la aplicaci\u00f3n web de iDRAC9. Un atacante remoto podr\u00eda potencialmente explotar esta vulnerabilidad para ejecutar HTML o JavaScript maliciosos en el navegador de una v\u00edctima enga\u00f1\u00e1ndola para que siga un enlace especialmente dise\u00f1ado" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "baseScore": 6.1, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE" }, "exploitabilityScore": 2.8, "impactScore": 2.7 } ], "cvssMetricV30": [ { "source": "security_alert@emc.com", "type": "Secondary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "baseScore": 6.1, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE" }, "exploitabilityScore": 2.8, "impactScore": 2.7 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "baseScore": 4.3, "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "availabilityImpact": "NONE" }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "security_alert@emc.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-79" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-79" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "4.32.10.00", "matchCriteriaId": "61EDDB16-D51C-440B-AEB5-3F087BC5E5A0" }, { "vulnerable": true, "criteria": "cpe:2.3:o:dell:idrac9_firmware:4.40.00.00:*:*:*:*:*:*:*", "matchCriteriaId": "F478B785-B01A-4715-A2E0-ED239299BDE0" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:dell:idrac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "BD8B684E-092F-496C-9D94-51CCD1F3575A" } ] } ] } ], "references": [ { "url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability", "source": "security_alert@emc.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] } ] }