{ "id": "CVE-2023-38532", "sourceIdentifier": "productcert@siemens.com", "published": "2023-08-08T10:15:16.403", "lastModified": "2023-11-14T11:15:10.847", "vulnStatus": "Modified", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.8, "impactScore": 3.6 }, { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "HIGH", "baseScore": 6.6, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.8, "impactScore": 4.7 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-770" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-770" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "34.1", "versionEndExcluding": "34.1.258", "matchCriteriaId": "E7751190-C386-451B-88B5-4BB4DCBFCE44" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "35.0", "versionEndExcluding": "35.0.254", "matchCriteriaId": "0B5F1A02-44EB-45AA-B071-764B64473313" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "versionStartIncluding": "35.1", "versionEndExcluding": "35.1.171", "matchCriteriaId": "EA7FF725-2396-492A-8B97-CA77B4EFCC48" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "versionStartIncluding": "14.2", "versionEndExcluding": "14.2.0.6", "matchCriteriaId": "7E1EFF45-5311-4E89-B736-271EF3C0C232" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*", "matchCriteriaId": "F859B7F9-2AD8-4B2E-9E26-7DEE54160348" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*", "matchCriteriaId": "8048B948-FD64-44FA-B5C3-52966997A1A4" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }