{ "id": "CVE-2024-32741", "sourceIdentifier": "productcert@siemens.com", "published": "2024-05-14T16:17:11.640", "lastModified": "2024-05-14T19:17:55.627", "vulnStatus": "Awaiting Analysis", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC CN 4100 (todas las versiones < V3.0). El dispositivo afectado contiene una contrase\u00f1a codificada que se utiliza para el usuario privilegiado del sistema \"root\" y para el cargador de arranque \"GRUB\" de forma predeterminada. Un atacante que logra descifrar el hash de la contrase\u00f1a obtiene acceso root al dispositivo." } ], "metrics": { "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 6.0 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-259" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html", "source": "productcert@siemens.com" } ] }