{ "id": "CVE-2024-0554", "sourceIdentifier": "cve-coordination@incibe.es", "published": "2024-01-16T11:15:07.933", "lastModified": "2024-01-23T19:37:17.313", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A Cross-site scripting (XSS) vulnerability has been found on WIC1200, affecting version 1.1. An authenticated user could store a malicious javascript payload in the device model parameter via '/setup/diags_ir_learn.asp', allowing the attacker to retrieve the session details of another user." }, { "lang": "es", "value": "Se ha encontrado una vulnerabilidad de Cross-site scripting (XSS) en WIC1200, que afecta a la versi\u00f3n 1.1. Un usuario autenticado podr\u00eda almacenar un payload de JavaScript malicioso en el par\u00e1metro device model a trav\u00e9s de '/setup/diags_ir_learn.asp', lo que permitir\u00eda al atacante recuperar los detalles de la sesi\u00f3n de otro usuario." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.3, "impactScore": 2.7 }, { "source": "cve-coordination@incibe.es", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "LOW", "baseScore": 5.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.1, "impactScore": 3.4 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-79" } ] }, { "source": "cve-coordination@incibe.es", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-79" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:xantech:wic1200_firmware:1.1:*:*:*:*:*:*:*", "matchCriteriaId": "27A5FA72-8BA5-4BE7-89D2-8D85C1554A8A" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:xantech:wic1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "04CACDA7-1954-4FDE-998A-E5675B65787F" } ] } ] } ], "references": [ { "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-full-compass-systems-wic1200", "source": "cve-coordination@incibe.es", "tags": [ "Third Party Advisory" ] } ] }