{ "id": "CVE-2024-23798", "sourceIdentifier": "productcert@siemens.com", "published": "2024-02-13T09:15:48.170", "lastModified": "2024-02-13T19:21:49.827", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones < V2201.0012), Tecnomatix Plant Simulation V2302 (Todas las versiones < V2302.0006). Las aplicaciones afectadas contienen una vulnerabilidad de desbordamiento de pila al analizar archivos WRL especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual." } ], "metrics": { "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-787" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-121" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*", "versionEndExcluding": "2201.0012", "matchCriteriaId": "92315B86-671A-48F9-9D7D-C638DABD8520" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*", "versionStartIncluding": "2302.0", "versionEndExcluding": "2302.0006", "matchCriteriaId": "D222D65A-C271-4BE4-8139-DB5F38D053D5" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html", "source": "productcert@siemens.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ] } ] }