{ "id": "CVE-2023-0027", "sourceIdentifier": "PSIRT@rockwellautomation.com", "published": "2023-03-17T17:15:11.307", "lastModified": "2024-11-21T07:36:25.453", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Rockwell Automation Modbus TCP Server AOI prior to 2.04.00 is vulnerable to an unauthorized user sending a malformed message that could cause the controller to respond with a copy of the most recent response to the last valid request. If exploited, an unauthorized user could read the connected device\u2019s Modbus TCP Server AOI information.\n\n" } ], "metrics": { "cvssMetricV31": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "baseScore": 5.3, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "availabilityImpact": "NONE" }, "exploitabilityScore": 3.9, "impactScore": 1.4 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "baseScore": 4.3, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "availabilityImpact": "NONE" }, "exploitabilityScore": 2.8, "impactScore": 1.4 } ] }, "weaknesses": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-200" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-200" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:rockwellautomation:modbus_tcp_server_add_on_instructions:*:*:*:*:*:*:*:*", "versionStartIncluding": "2.00.00", "versionEndExcluding": "2.04.00", "matchCriteriaId": "5D5053BE-2C68-4505-8B9D-D80A58C28952" } ] } ] } ], "references": [ { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1138766", "source": "PSIRT@rockwellautomation.com", "tags": [ "Permissions Required", "Vendor Advisory" ] }, { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1138766", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Vendor Advisory" ] } ] }