{ "id": "CVE-2022-29097", "sourceIdentifier": "security_alert@emc.com", "published": "2022-06-24T17:15:08.700", "lastModified": "2022-07-06T14:50:20.827", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Dell WMS 3.6.1 and below contains a Path Traversal vulnerability in Device API. A remote attacker could potentially exploit this vulnerability, to gain unauthorized read access to the files stored on the server filesystem, with the privileges of the running web application." }, { "lang": "es", "value": "Dell WMS versiones 3.6.1 y anteriores, contienen una vulnerabilidad de Salto de Ruta en la API del dispositivo. Un atacante remoto podr\u00eda explotar esta vulnerabilidad, para conseguir acceso de lectura no autorizado a los archivos almacenados en el sistema de archivos del servidor, con los privilegios de la aplicaci\u00f3n web en ejecuci\u00f3n" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.2, "impactScore": 3.6 }, { "source": "security_alert@emc.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.2, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "SINGLE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.0 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.0, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-22" } ] }, { "source": "security_alert@emc.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-23" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:dell:wyse_management_suite:*:*:*:*:*:*:*:*", "versionEndIncluding": "3.6.1", "matchCriteriaId": "F87482B6-A201-45BD-B8C4-679EBFF3D075" } ] } ] } ], "references": [ { "url": "https://www.dell.com/support/kbdoc/en-us/000200215/dsa-2022-143-dell-wyse-management-suite-security-update-for-multiple-vulnerabilities", "source": "security_alert@emc.com", "tags": [ "Vendor Advisory" ] } ] }