{ "id": "CVE-2023-35796", "sourceIdentifier": "productcert@siemens.com", "published": "2023-10-10T11:15:11.733", "lastModified": "2023-10-24T12:25:01.420", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)" }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEMA Server V14 (todas las versiones). La aplicaci\u00f3n afectada sanitiza incorrectamente ciertos datos de configuraci\u00f3n SNMP recuperados de los dispositivos monitorizados. Un atacante con acceso a un dispositivo monitorizado podr\u00eda realizar un ataque de Cross-Site Scripting (XSS) almacenado que puede llevar a la ejecuci\u00f3n de c\u00f3digo arbitrario con privilegios \"SYSTEM\" en el servidor de aplicaciones. (ZDI-CAN-19823)" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.0, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 2.3, "impactScore": 6.0 }, { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "HIGH", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.6, "impactScore": 6.0 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-79" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:*:*:*:*:*:*:*", "matchCriteriaId": "85D4624C-8FF6-43E7-9098-5BD106EF6972" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf", "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ] } ] }