{ "id": "CVE-2020-5374", "sourceIdentifier": "security_alert@emc.com", "published": "2020-07-14T20:15:11.660", "lastModified": "2020-07-21T15:23:12.920", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain a hard-coded cryptographic key vulnerability. A remote unauthenticated attacker may exploit this vulnerability to gain access to the appliance data for remotely managed devices." }, { "lang": "es", "value": "Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) para SCCM y SCVMM versiones anteriores a 7.2.1, contiene una vulnerabilidad de clave embebida. Un atacante remoto no autenticado puede explotar esta vulnerabilidad para conseguir acceso a los datos del dispositivo para dispositivos administrados remotamente" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 }, { "source": "security_alert@emc.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:L", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "availabilityImpact": "LOW", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.3 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 10.0, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-798" } ] }, { "source": "security_alert@emc.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-256" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:dell:emc_omimssc_for_sccm:*:*:*:*:*:*:*:*", "versionEndExcluding": "7.2.1", "matchCriteriaId": "C1F82F95-99C6-44BA-9CB9-2D4ED583B41B" }, { "vulnerable": true, "criteria": "cpe:2.3:a:dell:emc_omimssc_for_scvmm:*:*:*:*:*:*:*:*", "versionEndExcluding": "7.2.1", "matchCriteriaId": "120662C3-E1C7-4092-876B-50713AD87022" } ] } ] } ], "references": [ { "url": "https://www.dell.com/support/article/en-us/sln322169/dsa-2020-163-dell-emc-openmanage-integration-for-microsoft-system-center-multiple-vulnerabilities?lang=en", "source": "security_alert@emc.com", "tags": [ "Vendor Advisory" ] } ] }