{ "id": "CVE-2023-23784", "sourceIdentifier": "psirt@fortinet.com", "published": "2023-02-16T19:15:14.517", "lastModified": "2023-11-07T04:07:58.743", "vulnStatus": "Modified", "descriptions": [ { "lang": "en", "value": "A relative path traversal in Fortinet FortiWeb version 7.0.0 through 7.0.2, FortiWeb version 6.3.6 through 6.3.20, FortiWeb 6.4 all versions allows attacker to information disclosure via specially crafted web requests." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 3.6 }, { "source": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 5.7, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.1, "impactScore": 3.6 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-22" } ] }, { "source": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-23" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*", "versionStartIncluding": "6.3.6", "versionEndExcluding": "6.3.21", "matchCriteriaId": "065777FA-70C7-418D-924E-379840F3C46B" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*", "versionStartIncluding": "6.4.0", "versionEndIncluding": "6.4.2", "matchCriteriaId": "F6B93ABE-8620-4253-83C0-3D2228D20118" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*", "versionStartIncluding": "7.0.0", "versionEndExcluding": "7.0.3", "matchCriteriaId": "A9851C39-C7A5-4E0F-BF5D-0E3D2D36AAAE" } ] } ] } ], "references": [ { "url": "https://fortiguard.com/psirt/FG-IR-22-251", "source": "psirt@fortinet.com", "tags": [ "Vendor Advisory" ] } ] }