{ "id": "CVE-2024-8957", "sourceIdentifier": "disclosure@vulncheck.com", "published": "2024-09-17T21:15:13.423", "lastModified": "2024-10-01T17:49:25.573", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices." }, { "lang": "es", "value": "PTZOptics PT30X-SDI/NDI-xx anterior al firmware 6.3.40 es vulnerable a un problema de inyecci\u00f3n de comandos del sistema operativo. La c\u00e1mara no valida suficientemente el valor de configuraci\u00f3n ntp_addr, lo que puede provocar la ejecuci\u00f3n de comandos arbitrarios cuando se inicia ntp_client. Cuando se combina con CVE-2024-8956, un atacante remoto y no autenticado puede ejecutar comandos arbitrarios del sistema operativo en los dispositivos afectados." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 }, { "source": "disclosure@vulncheck.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.2, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-78" } ] }, { "source": "disclosure@vulncheck.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-78" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "6.3.40", "matchCriteriaId": "604C6EEF-4273-4366-AFF2-86C3183F545D" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:ptzoptics:pt30x-sdi:-:*:*:*:*:*:*:*", "matchCriteriaId": "7462D89D-2105-417F-AB0E-D23C288156C8" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "6.3.40", "matchCriteriaId": "B410E242-DFEE-449D-9687-6F4D0BEB8F63" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:-:*:*:*:*:*:*:*", "matchCriteriaId": "C8F75E95-D59D-45D4-B798-D0493642F53E" } ] } ] } ], "references": [ { "url": "https://ptzoptics.com/firmware-changelog/", "source": "disclosure@vulncheck.com", "tags": [ "Release Notes" ] }, { "url": "https://vulncheck.com/advisories/ptzoptics-command-injection", "source": "disclosure@vulncheck.com", "tags": [ "Third Party Advisory" ] } ] }