{ "id": "CVE-2021-33714", "sourceIdentifier": "productcert@siemens.com", "published": "2021-07-13T11:15:10.043", "lastModified": "2021-07-20T18:33:42.790", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a missing check for the validity of an iterator leads to NULL pointer deference condition, causing the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en JT Utilities (Todas las versiones anteriores a V13.0.2.0). Cuando se analizan los archivos JT especialmente dise\u00f1ados, la falta de comprobaci\u00f3n de la validez de un iterador conlleva a una condici\u00f3n de desreferencia del puntero NULL, causando el bloqueo de la aplicaci\u00f3n. Un atacante podr\u00eda aprovechar esta vulnerabilidad para causar una condici\u00f3n de Denegaci\u00f3n de Servicio en la aplicaci\u00f3n" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.8, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P", "accessVector": "LOCAL", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 2.1 }, "baseSeverity": "LOW", "exploitabilityScore": 3.9, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-476" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*", "versionEndExcluding": "13.0.2.0", "matchCriteriaId": "81FB113B-95A2-462D-A00E-88C09635900C" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf", "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ] } ] }