{ "id": "CVE-2021-33729", "sourceIdentifier": "productcert@siemens.com", "published": "2021-10-12T10:15:12.060", "lastModified": "2021-10-18T15:05:44.140", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker that is able to import firmware containers to an affected system could execute arbitrary commands in the local database." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones anteriores a V1.0 SP2 Update 1). Un atacante autenticado que sea capaz de importar contenedores de firmware a un sistema afectado podr\u00eda ejecutar comandos arbitrarios en la base de datos local" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "SINGLE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 6.5 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.0, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-89" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.0", "matchCriteriaId": "2B59D696-F272-40DA-8DC6-423D9E5026C0" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*", "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55" }, { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "5F2C66EC-5A29-4B92-AEDB-7DB8A5CA7391" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }