{ "id": "CVE-2021-37199", "sourceIdentifier": "productcert@siemens.com", "published": "2021-10-12T10:15:12.600", "lastModified": "2021-10-19T11:55:23.290", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINUMERIK 808D (All versions), SINUMERIK 828D (All versions < V4.95). Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINUMERIK 808D (Todas las versiones), SINUMERIK 828D (Todas las versiones anteriores a V4.95). Los dispositivos afectados no procesan correctamente determinados paquetes especialmente dise\u00f1ados enviados al puerto 102/tcp, lo que podr\u00eda permitir a un atacante causar una denegaci\u00f3n de servicio en el dispositivo" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8 }, "baseSeverity": "HIGH", "exploitabilityScore": 10.0, "impactScore": 6.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-787" } ] }, { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-122" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinumerik_808d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6656E410-ED0B-413E-A173-D21DA005123E" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:sinumerik_808d:-:*:*:*:*:*:*:*", "matchCriteriaId": "6B6A9DDC-D9C6-4497-8948-295C4AB567DA" } ] } ] }, { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "4.95", "matchCriteriaId": "2996DBE9-0573-4D62-A4E5-AE39F3A8978F" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D97047C-9772-4AEB-B993-131EBBAE33BA" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf", "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ] } ] }