{ "id": "CVE-2021-3958", "sourceIdentifier": "cve@usom.gov.tr", "published": "2021-11-16T16:15:06.873", "lastModified": "2023-03-26T20:15:07.267", "vulnStatus": "Modified", "descriptions": [ { "lang": "en", "value": "Improper Handling of Parameters vulnerability in Ipack Automation Systems Ipack SCADA Software allows : Blind SQL Injection.This issue affects Ipack SCADA Software: from unspecified before 1.1.0." }, { "lang": "es", "value": "Debido a un saneo inapropiado, iPack SCADA Automation software sufre una vulnerabilidad de inyecci\u00f3n SQL remota. Un atacante no autenticado con acceso a la web es capaz de extraer informaci\u00f3n cr\u00edtica del sistema" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 }, { "source": "cve@usom.gov.tr", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 7.5 }, "baseSeverity": "HIGH", "exploitabilityScore": 10.0, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-89" } ] }, { "source": "cve@usom.gov.tr", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-89" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:ipack:scada_automation:*:*:*:*:*:*:*:*", "versionEndExcluding": "1.1.0", "matchCriteriaId": "8D15023C-D4F7-4F82-A85E-E02215E3BB57" } ] } ] } ], "references": [ { "url": "https://github.com/paradessia/cve/blob/main/Ipack-Scada-Automation.txt", "source": "cve@usom.gov.tr", "tags": [ "Exploit", "Third Party Advisory" ] } ] }